andy_eade wrote:
I was really questioning whether I could use the screws as you would for normal drywall installation i.e. up through the drywall into the subfloor. I'm assuming that this is inadvisable for two reasons:
1) comprimising the mass with "holes".
2) Not enough depth for the screw to be drilled into and hold the weight of the drywall.
99.5% #2 and 0.5% #1.
I would actually advise you do
both screws about 1" from the
edge of the drywall strips into the subfloor
and 1x2 cleats along the joists. The screws in strips through to the subfloor will minimize the air gap (ideally none) between the subfloor, and the cleats will relieve pressure on the screw heads and act as insurance against sagging of the strips and/or failure of the screws. Imagine the screws failing and a piece falling down diagonally, bridging the upper leaf to the lower leaf!
:shock: You'd probably figure out that there was a problem but wouldn't be able to pinpoint it... And even if you could, imagine the multi-layer hole you'd have to make in order to fix it.
:roll:
Again, green glue may be useful to mitigate resonance of the subfloor and the drywall strips, all without adding any significant amount of weight to your beef-up materials.
I had planned to used GG on the last layer of 3 5/8th layers of the ceiling hung from the clips. Do you think it's worth using it on the beef up layers too? If it's going to make the difference between silencing my late night drumming from the upstairs or not then it's clearly worth the time, money and effort!
I would do it just for peace of mind's sake, since you can't do it after the fact. If cost is an issue, then keep in mind that you can get away with less than 100% of the optimal coverage and still get good results. I used about 70% of the optimal coverage so I could stretch the one case I purchased over a larger area. You can go as low as 50%. If I recall correctly, the optimal coverage is two tubes per 4x8 sheet, i.e., one tube per 16 square feet. 50% of that would be one tube per 32 square feet.
I am not beefing up above the control room. Mainly because one of the joist bays (the end one nearest the patio door) is full of plumbing and cables that would be an absolute nightmare to deal with. I also figure that 3 layers of 5/8" alone should give me enough isolation for the control room. Does that sound okay to you guys?
Hmmmmmm...
:roll: ...If the gap between upper and lower leaves is contiguous over all rooms (as I would expect it to be), and you have beefed up a portion of the upper leaf, then I would expect noise to travel
up from the live room (or vocal booth) through the lower leaf into the gap, then
sideways towards the area beneath the unbeefed upper leaf, then
up through the inferior upper leaf.
:?
Remember the "weakest link" theory! A soundproofing job's
best performance will be largely based on its
worst component.
:roll:
You know, Andy, aside from the drawing that John put together for your layout, and the photographs you have posted, you haven't posted any actual
drawings of the
construction details... May I recommend that you do that?
Drywall arrived today and is sitting in the garage looking all pretty. I took a picture especially for you Keith and will post it tommorrow. :D
Cool!!
8) It's funny -- as soon as I read "sitting in the garage looking all pretty," I flashed back to my drywall delivery photos -- and then I read your "picture especially for you Keith" and, well, my heart got all warm and fuzzy!
:lol:
--Keith
:mrgreen: