On Purpose Productions detached garage studio

Started by onpurposeproductions on 10 December 2008. 282 replies, 2008–2014. In the Library under Build diaries. Key posts in this thread.

Originally posted at johnlsayers.com, topic 11485.

Your certainly going for the mini traps! I thought the pic you posted the other day was just an optical illusion or you had really big hands :mrgreen:
IMG_1665.JPG
IMG_1665.JPG
onpurposeproductions wrote:
onpurposeproductions wrote:
I think I'd really prefer panels similar to those used in movie theaters (generally 1" thick but covering a much larger surface area).
John - if I went this route, is there a particular product that you'd recommend? Owens Corning 703 seemed to be impossible to find (in Canada) when I looked earlier during my build.
Roxul (Canadian company) have a similar range to OC and it's cheaper also. http://www.roxul.com/
John Sayers wrote:
Roxul (Canadian company) have a similar range to OC and it's cheaper also.
Yeah, I used Roxul's industrial grade product, RHT. I went with RHT80 (8.0 lbs/ft3). They of course also have RHT100 and RHT 120, (10 and 12 lbs/ft3 respectively), which would presumably be more rigid - have you used those before with good success at mid to high frequency absorption? I had the impression that they may be too dense for an effective wall panel?
check out roxul AFB it has a density of 2.8 pcf where as 703 has a density of 3 pcf. I read here somewhere that about 5 pcf or 48 kg/m is ideal, If your interested an unopened bag of the 23" wide Roxul comfort batt R14 has a density of about 5.5 pcf, you could put a couple bags in each corner for bass trapping see how it works.
I read here somewhere that about 5 pcf or 48 kg/m is ideal,
Actually, 3 pcf is 48 kg/m3! 5 pcf is 80 kg/m3.
Roxul comfort batt R14 has a density of about 5.5 pcf, you could put a couple bags in each corner for bass trapping see how it works.
That's REALLY dense! It's nearly 90 kg/m3. Probably not going too help much for bass trapping. Lower density is actually better for low frequency trapping.
check out roxul AFB it has a density of 2.8 pcf
That sounds about right. - Stuart -
Roxul comfort batt R14 has a density of about 5.5 pcf, you could put a couple bags in each corner for bass trapping see how it works.
That's REALLY dense! It's nearly 90 kg/m3. Probably not going too help much for bass trapping. Lower density is actually better for low frequency trapping.
oops, i was thinking 5 pcf was ideal just trying to remember numbers off the top of my head, an unopened bag is definitly not 5 pcf. I do remember i calculated it to be slightly denser than ideal, the bag weighs 41 lbs (18.6 kg) and measures # Length: 47" (1194 mm) # Width: 23" (584 mm) # Thickness: 3½" (89 mm) X 8 batts = 28" (712mm) (uncompressed height) I forget what height the bag is compressed to but somewhere around 18"-22" lets say 20"(508mm) V=.3542 m3 so approx density is 52.51kg/m3. But for some reason 55 kg/m3 is what i remember, but clearly my memory is questionable.
this design is perfect for what I want to do...
How much did this set up cost you? What was the starting dimensions of your building?