Hi Everyone,
My name is hally and I am located near Dublin in Ireland…
I am at the planning stage of my studio build and need help making a few decisions on how I propose to isolate the control room from the rest of the dwelling. The control room will be used for mixing / tracking music; it will also act as a video editing suite and for recording acoustic instruments and vocals. I also wish to construct a machine room adjacent to the control room. On completion of the control room I will be starting construction of the rest of the studio, 2 live rooms, toilet, and green room. The Control also needs to be sufficiently soundproofed to eliminate as much sound coming from the live rooms.
I previously posted my plans for the whole studio which includes other areas of the building (live rooms, etc) but I became so overwhelmed by the entire project I have decided to work on a room by room basis. This suits my head and my budget. It also means that when this control room is complete I can move in to begin work while continuing to build the rest of the studio.
My main goal for the Control Room which is an attic space ( an inverted V shape) is to limit outside noise (dogs, heavy vehicles, etc) from entering the room and isolate the noise within the room from the rest of the dwelling. The sound levels within the CR will be generally at normal mixing/ recording levels. The work to date carried out on this attic room has been to create an entrance into the room through what used to be a 12” Cavity gable end block wall and the installation of a timber stairs leading up to this entrance. As you will see in the pictures below the room is bear, a blank canvas you might say.
Room Dimensions: W 12’ X L 24’ X H 7’8” @ the apex of the roof.
Floor Square footage: 288sq feet
The Roof: Tiles sitting on 2 X 1 battens on felt on rafters on 8” x 3” purlins…
The Block Walls: 12” Cavity Concrete walls, consisting of (from the exterior inwards) Plaster Skim, 4” block, then cavity, then aerobord, then 4” block. (Cross section pic. below)
Rafters: 5” X 1 ½” @ 16” centers, 18 rafters running each side of the apex.
Floor Joists: 7” X 2” @ 16” centers. These joists are supported (sitting on ) the exterior walls and they span to about half way across the width of the building where they are nailed together and sit on an internal 4” block wall below.
Partition Wall: 3” X 1 ½” Stud partition acting as perlin to support the rafters. I have been advised by an engineer that it is possible to move this wall back 4’ by inserting a Reinforced Steel Joist to extend the width of the room to 16’ if this alteration would be acoustically benificial to the room...
Here are a few floor plans, pictures and 3D shots of the room
Aerial Views of the attic space and machine room
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-aerial-2.jpg
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-aerial-1.jpg
Cross Section Drawing of the Back of the Building
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-back-section-house.jpg
Floor Plan Drawing
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-floorplan.jpg
Photographs of the Room as it is now
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/controlroom-entrance-view.jpg
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-view-from-window.jpg
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-entrance-machine-room.jpg
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-rafter-detail.jpg
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/cr-staires-landing.jpg
Cross Section of External Block Walls
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/wall-crosssection-detail.jpg
If anyone requires more details about the structure of the building don’t hesitate to ask, I have drawing plans of concrete slab foundation, etc.
Testing with Sound level Meter
I hooked up a pair of speakers in the room below the attic space and played a drum loop and a deep bass pattern through them. The sound level meter was set to slow dBC reading and the level next to the speakers was max 103.3 dBC. Upstairs the meter read 87dBC and the floor joists were buzzing (it was a very deep bass sound) The reading in the attic normally without music blasting from below with normal everyday passing traffic, water tank, birds, etc was from 47 – 55 dBC.
My Plan for Soundproofing
1.To treat the Floor of the attic/ Control Room I am considering following Rods guidelines from his book. My joists as they are do not have any cross bridging…
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/joist-detail-1.jpg
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/joist-detail-2.jpg
2.For the existing partition wall made from 3” X 1 ½” Studs (this wall cannot be moved as it is load bearing) I thought I would again follow Rods guidelines by adding another 3” X 1 ½” Stud partition behind it with air space between them, both these walls will be sitting directly onto the joists.
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/wall-partition-detail.jpg
3.The existing cavity block walls, it has been suggested to me that the STC of these walls would be pretty good as they are, so I thought I would just add one layer of plasterboard for aesthetic reasons. Ideally I would like to insulate these block walls with some fiberglass behind the plasterboard but this would mean erecting some studs on the walls and I think I would be then creating an extra leaf to the wall.
4.The roof, this is really tricky and to be honest I am lost as to the best way to approach it. The building regulations here in Ireland state you must leave a 50mm gap between the roofing felt and whatever insulation you put in the roof. This is to allow the roof to breed and something to do with condensation (i think). Head room is at a premium in this room so I am unsure what my options are. But to start the ball rolling here’s what I’m thinking. Roof Tiles, felt, air gap, 2 layers of 9mm or 11mm plasterboard, standard fiberglass, resilient channels, 2 layers 9mm or 11mm plasterboard. All sealed appropriately. Below is a cross sections drawing of the proposed roof treatment….
External image, not preserved — original: http://www.jamesmmedia.com/controlroom/roof-soundproofing-cross.jpg
My Questions;
THE FLOOR
1.Is the treatment for the floor of this room the best option or should I be considering other methods?
2.Assuming my suggestion for the floor is the best way to go is it safe to assume that the 7” X 2” floor joists @ 16” centers will have no problem in carrying the extra load?
3.Currently there is no bridging between the floor joists, should this be still be installed after the plasterboard has been put between the joists?
THE PARTITION WALL
1.Is my approach here the best option?
2.Behind the existing single layer of plasterboard there is a thin sheet of plastic, does this need to come out and should I just remove the single layer of plasterboard and start with the new installation?
THE EXISTING CAVITY BLOCK WALLS
1.Again, are my proposals for these walls ok, any suggestions welcome?
THE ROOF
1.I am really just guessing as to how to treat this section of the room and because it covers such a large surface area of the room its imperative that I get it right, please advise as to my best options here?
GENERAL
1.Should I be thinking about altering the internal shape of the room, ie. Slanted walls, etc.
Thank you for taking the time to read my post and I look forward to your responses and advise.
Warm regards
hally