That means no insulation voids.
How would you fill the void here in the double stud pic? Use 25mm batts laid horizontally all the way along in between the studs and the main thick batts?
The larger room is not decoupled from the structure. But it will have the block outer leaf and a stud inner leaf, which goes up to the roof joists. The ceiling in that room should be attached directly to the joists. I'll get the architect to clarify on the drawing. Thanks!but the larger room design seems off to me. It appears to have an inner leaf everywhere except the windows. Also, the ceiling it's decoupled so why are you adding an inner leaf there at all?
Yes, the gap size will be the same - I'll get all the changes done to the drawing at the same time. The 12th Sept drawing was my scribbling.Also, why aren't you maintaining your spring gap size between the two rooms the same as you are to the exterior wall? That smaller gap will increase your resonant frequency. In your Sept 12th diagram, it looks like you have things correct. This new one isn't the same as you had initially planned.
Thanks for pointing these things out!