I have a post here... http://www.johnlsayers.com/phpBB2/viewtopic.php?t=5527
Everything is going well I just have a question about the slatwalls....Is is it ok to have hanger traps in the cavity of the slatwall?I have a bit of space in there and from listening to the room I'm pretty sure I'm going to need all the bass trapping I can get.
I will be putting hanger traps under the stairs as John suggested as well.
Thanks,
Chris
Slatwall and Hanger traps
Originally posted at johnlsayers.com, topic 5610.
Slatwall is another word for Helmholtz trap - the formula is based on 48 kG/m^3 rigid fiberglass insulation by Owens Corning, and the results will change unpredictably if you change the basics.
If you're just putting wide-spaced slats over a corner absorber, then sure; if you're actually tuning for a specific frequency (like your 2:1:1 room ratios) then I'd stick to ONE type of trap... Steve