Roxul ... RHT or RXL

Started by fisher of men on 29 November 2005. 5 replies.

Originally posted at johnlsayers.com, topic 4744.

HI, one quick question. Which roxul product compares to owens 703 RXL 40 or RHT 40 Thanks, steve
The RXL is supposed to be a bit stiffer, so would stay put better between studs; the RHT is more of a tank wrap with more flexibility at high temperatures, so would tend to sag more in most of our typical applications. Neither product is a direct replacement for 703; that is a rigid fiberglass product with 3 PCF density, while both of the Roxul products you asked about are 4 PCF. For actual in-room acoustic treatment, the roxuls would give a bit better LF absorption per unit thickness than 703, but probably a bit LESS higher frequency absorption especially at the more normal, NON perpendicular incidence. This would usually be a GOOD thing for the most part, as it would keep the room a bit brighter sounding. For in-wall insulation, 2.5 PCF is about as high as you'd want; lower density improves on LF performance (just backward from intuition, like a lot of things acoustic) - in fact, the standard house insulation (fluffy fiberglass) does as well inside a wall as the more expensive rigid board types... Steve
HI and thanks for your quick reply, I will be useing this stuff for celing clouds, corner traps , wall treatment and building a soffit. with wood frame with cloth covering. so it will need to be as stiff as or close to the 703 what do you think?? I would have used the 703 but AMS cant get it for 2 months! and there fluffy stuff is back ordered for 5 weeks! Thanks, steve
Ahhh, AMS. That's where I got my drywall and where I plan to get my insulation too. I like 'em.
RXL. Definitely. If things are normal, you will even save money over using 703; and I defy anyone to tell the diff once the cloth is on... Steve
Cool ! Thank you for your help :D steve