Wow! You guys are loud!
Actually, we're not
that loud... It's just a 3 peice, gtr, bass, drums and vocals. Drummer doesn't hit that hard too. The meter is very good though, and doesn't do a whole lot of averaging, thus it may appear to read higher than others. Also, I was using the C weighting as opposed to the more common A weighting, so I was getting much more low frequency into my reading than others who use the A weighting (which is really geared more towards speech).
...given the fact that you're coupling your walls to your ceilings
I am coupling the studs to the joists above, yes, but I am not coupling the drywall on the ceiling to the drywall on the walls. I can't afford to build a second ceiling, either in terms of headroom, or budget, and thus if TL or STC has to suffer, so be it....
I might have to re-visit my numbers....55 dB SPL on the main floor, while it would be great, and would put the leakage down around the noise floor for, it just might not be possible.
I was getting 83 dB on the main floor, with just the floorboard/joists covered in roxull....no ceiling was present. Assuming my existing "ceiling" (open joists/floorboards) has a performance similar to a single wall with single sheet drywall, it would be STC 34. My ceiling offered a 20 dB reduction, which would be like a single wall's effectiveness at around 150 Hz (According to the NRC research). Now, according to the same paper, a 2X drywall + RC on one side wall will have about 45 dB TL at 150 Hz, which is like a 25 dB improvement over the simple wall.
I realize that things like flanking and HVAC can have a big effect on the overall acheived TL. Also, I realize that TL falls off pretty fast below 100Hz or so, except with very thick walls (large air gaps). I know that I will not acheive the published STC or TL curve, as my construction will have more imperfections than a lab speciment (i.e. I have lighting fixtures to contend with). But would it be reasonable to assume that I can get to about 80% of the lab tested result, given some attention to details during the construction phase? Acheiving an additional 20dB loss at 150Hz would be "good enough" as far as I'm concerned.
Are you also going to "beef up" the outer leaf (current ceiling/floor layer) with more drywall? if you are trying to get good iso from upstairs to down, then you should definitely do this.
Hi Dan, I'd like to do this...but need to consult some span tables to see if my joists can handle that extra dead load. It'd be a tough job too, give nall the HVAC running in the joist cavities, they'd have to be pulled out individually, and then the floor strengthened, then put back in.
Cheers,
Kris