Hey everyone, I'm new around here so be gentle!
A wise sage once told me too much info is the same as a lack of knowledge but I thought... "meh, I need to do as much research as humanely possible before I spend my hard earned cash".... However after days and nights of hard toil, watering eyes from reading copious amounts of forums I've realised... maybe I'm wrong.
Hard facts are; I've inherited a small space in London England, 15ft long, 9ft 4 wide, 9ft 8 from a 10 inch raised floor to the actual ceiling
metric version reads, 4.57 metres long, 2.84 metres wide, 2.94 metres from 25cm raised floor to actual ceiling The ceiling is also dropped but I'm pretty sure I will remove it as build quality is poor and it is too low (8ft from raised floor).
The unit on the 2nd floor of a large industrial building and at the moment sound is leaking and entering from the adjacent corridor and the corridor from the floor above. I want to be able to crank up my speakers in the day and not disturb the units in the vicinity + record vocals without being heard from outside the room.
I'm confident I need to build a studwall-placing them on neoprene type isolators (for decoupling) with acoustic board and rock wool with an airgap to give good isolation as well as the same for the ceiling to create a room within a room, but I'm concerned about flanking and the floor construction.
I'm getting conficting information- underneath the current raised floor (just rockwool, fibreboard and wood)The floor is solid feels like maybe concrete with tiles on top. some say rip out the current raised floor and build a joist type raised floor on uboats-others say u boats have no benefit and any floated floor construction is useless unless its precisely engineered and expensive. I say aahhhhh, I'm confused, what do I do? do I even need it?
I have some pics if this helps
any advice appreciated
ps. a little side note: though the walls are solid brick there is part of one wall that looks like it was a doorway previously that has filled in with breeze block but still recessed a little as in not flush. Should I add in fluffy rockwool and board it up before constructing inner walls?
Thanks
Rob
Basic plans listed below
Remove existing ceiling and floor
1. Build stud walls away from existing walls
- build all 4 walls for room within a room construction
- place on studwall isolators 1200 x 90 x 6mm
- fill with Rockwool RWA45 insulation
- add 2 layers of acoustic plasterboard to inside face only
- use green glue between layers of plasterboard
- seal all joins and perimeters with acoustic sealant (seal layer 1 before adding layer 2)
2. Build ceiling on top of existing walls
- like the new walls this ceiling should not touch the existing structure at all
- fill with Rockwool RWA45 insulation
- add 2 layers of acoustic plasterboard to inside face only
- use green glue between layers of plasterboard
- seal all joins and perimeters with acoustic sealant (seal layer 1 before adding layer 2)
3. Build raised floor
- should sit inside of new walls with 10mm expansion gap all the way around
- place on joist cradles every 400mm http://www.eqacoustics.com/products-pag ... -isolators
- you can reuse your existing floor timber and insulation if you wish
- use 2 layers of 18mm MDF with a layer of acoustic plasterboard between them
- put green glue between the layers of board
- seal all joins and perimeters with acoustic sealant (seal layer 1 before adding layer 2, 3 etc)
a heavy door with acoustic seals
External image, not preserved — original: http://i1246.photobucket.com/albums/gg606/robsumbody/1TheFloorunderneath_zps8c280d69.jpg
External image, not preserved — original: http://i1246.photobucket.com/albums/gg606/robsumbody/2Thefloorgap_zpsa34131c9.jpg
External image, not preserved — original: http://i1246.photobucket.com/albums/gg606/robsumbody/Theceling_zpsd2f4dbd9.jpg