Started by callaghan on 22 February 2010. 3 replies.

Originally posted at johnlsayers.com, topic 14094.

Hi to all :D . Do you think there could be any cons in applying John's inside-out ceiling layout to the stud walls? That is with the studs passing trough the whole insulation-drywall-insulation system just like the joists do on the inside-out ceiling. Since space is an issue for me this could save me a little space while still keeping the stud size big enough to be load bearing... This is a top view of the outer existing (concrete) wall and of the inner stud wall:
Image not preserved: Pat inside out wall.jpg
Of course this would mean (especially if studs are placed 16 O.C.) a lot of drywall and rockwool cutting and resizing but if it's ok I guess it could be worth the extra work :mrgreen: ... Do you think the efficiency of the system would suffer any major loss in this layout :? ? Thanks for your help Pat
Interesting idea mate but unfortunately the sound will travel straight through the studs with no drywall to stop it. :(
Thanks John! errr.. I guess it was too good to be true :oops: ... And do you think that any of these 3 alternatives could avoid sound to travel through the stud while still maintaining load bearing characteristics? (assuming 2x4 is what I need for bearing) a) with single 2x4 stud leaving the outer end covered by a thinner layer of rockwool:
Image not preserved: Pat inside out wall a.jpg
b) separate 50x50mm studs on each side screwed together trough the drywall in the same spot (I guess coupling will occur through the screw, but could it be considered a negligible amount of coupling?)
Image not preserved: Pat inside out wall b.jpg
c) separate 50x50mm studs on each side staggered 12" O.C.
Image not preserved: Pat inside out wall c.jpg
Thanks for your help :D ... Pat