Under the floor or on the wall??

Post by hugo_inside »

what is the best way to put PVC ducts for electric wiring?? I see most people in this forum chose the floor for wiring... My electrician doesn't do this before... there is no problem if duct goes on the walls?

this is the room...
LiveWire
Posts: 28
Joined: Wed Aug 24, 2005 3:09 pm
Location: CT
Contact:

Post by LiveWire »

why is your electrical going in conduit?

You should have conduit for audio cabling, but I am sure BX or romex in the wall will meet your building code.
http://www.livewiresi.com

Professional Audio and Video Systems
Design-Sales-Intergration-Service
knightfly
Senior Member
Posts: 6976
Joined: Sun Mar 16, 2003 11:11 am
Location: West Coast, USA

Post by knightfly »

Not really; commercial facilities (which Hugo's will be) have stricter codes in most places.

Hugo, at this time (building too fast, planning too slow) you're pretty much limited to surface mounted METAL conduit, unless you can convince your local inspectors that there won't be a risk of physical damage to plastic conduit -

IF this proves to be true (if I'm not missing an important point) then running the conduit at about 0.6 meters above the floor will allow you to mount your wall absorbers/treatments just above the conduit so it doesn't look out of place so much.

Don't run your power conduits closer than 1/3 meter to any audio wires or their conduits, or you'll get hum in the audio lines... Steve
Soooo, when a Musician dies, do they hear the white noise at the end of the tunnel??!? Hmmmm...
LiveWire
Posts: 28
Joined: Wed Aug 24, 2005 3:09 pm
Location: CT
Contact:

Post by LiveWire »

I din't realize that it was a commercial space, by the picture I thought it was his basement.

Sorry about that. If it's a commercial space then your right the codes are totally different
http://www.livewiresi.com

Professional Audio and Video Systems
Design-Sales-Intergration-Service
knightfly
Senior Member
Posts: 6976
Joined: Sun Mar 16, 2003 11:11 am
Location: West Coast, USA

Post by knightfly »

No prob; with only 3 posts so far, unless you've been lurking for a year or two you'd have no way of knowing from just that post. I wasn't jumping on you, we don't do that here (or else :evil: ) - only clarifying the situation for minimal confusion.

Welcome to the board, BTW - Apparently Keith (our "Mere Mortal Walmart Greeter") must be sleeping on the job again - :lol: ... Steve
Soooo, when a Musician dies, do they hear the white noise at the end of the tunnel??!? Hmmmm...
Post Reply